Ty5337
WebJun 4, 2024 · Patrones de descarga rociadores tfp710 10-2014 1. General Description Information for the Sprinkler Spray Patterns provided in this document is provided in one of four methods: • Spray Profile Pattern • Cross Sectional Pattern • Wall Wetting Pattern • Average Applied Density For each method a representative sample of a TFP sprinkler was … WebThông tin kỹ thuật đầu phun Sprinkler Tyco hướng lên TY5137. - Đạt tiêu chuẩn: UL, C-UL, FM. - Áp lực làm việc tối đa: 175 psi (12.1 bar). - Lưu lượng phun: K=11.2 GPM/psi½ (161.3 LPM/bar½). - Kích cỡ đầu phun: 3/4 inch NPT (DN20). - Kích thước ống thủy tinh: 3mm. - Nhiệt độ kích hoạt ...
Ty5337
Did you know?
http://codienhoangha.com/vi/san-pham/Dau-sprinkler/Dau-phun-Spinkler-Tyco-canh-tuong-ngang.html
WebThe TYCO Model SW-20 and SW-24, 11.2 K-factor, Standard Response, Extended Coverage Ordinary Hazard (ECOH) Horizontal Sidewall Sprinklers are decorative glass bulb … WebSIn TY5332, TY5337 TeCh DATA TFP230 E lo s W -20/s W-24 horizontal Sidewall • ordinary hazard • 3 mm bulb • utilizes an extra large orifice (elo) that allows low water pressure requirements, while providing the flow required for extended coverage • sW-20 listed to a 16'-0" (4,9 m) wide and a 20'-0" (6,1 m) throw maximum coverage area
WebTY5337 is a re-designation for C5337. Technical. Data. Approvals. UL and C-UL Listed (Refer to the Design Criteria Section) Polyester coated sprinklers are UL and. C-UL Listed as … WebTyco Fire & Building Products
WebTY5337 – SW-24 TY5332 is a redesignation for C5332. TY5337 is a redesignation for C5337. Technical Data Approvals UL and C-UL Listed (Refer to the Design Criteria Section) Polyester coated sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. NYC under MEA 177-03-E.
WebTYCO TY5337 3/4 in. 200F 11.2K Horizontal Sidewall and Standard Response Sprinkler Head in Chrome. Part # T510739200. Item # 1959869. Mfr. Part # 51-073-9-200. X. POINTS. … camping breuilletWebTYCO TY5337 3/4 in. 200F 11.2K Horizontal Sidewall and Standard Response Sprinkler Head in Chrome . www.ferguson.com. LEAD LAW WARNING: In accordance with the US Federal … camping bretignolles sur merWebTY5337 - SW-24 TY5332 is a redesignation for C5332. TY5337 is a redesignation for C5337. Technical Data Approvals UL and C-UL Listed (Refer to the Design Criteria Section) Polyester coated sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. NYC … camping bretagne pas cher bord de merhttp://sincoid.com/product/tyco/Section2_Extended_Coverage/2-5.pdf camping bridal veil falls portlandhttp://www.nhatnam.com.vn/en/product/tyco-sprinkler-system/tyco-spinkler-head/horizonal-sidewall-sprinkler-tyco-ty53325337.html?p=3 camping brevard county floridaWebJul 7, 2024 · TY5337: Horizontal Sidewall: 11.2: 3/4 (20) OH: SR: EC: 175 (12.1) Find Tyco sprinkler heads for any application. Tyco is a massive company, and its size allows it to … first watch jacksonville floridaWebTY5337 SW-24 11.2k (K160) Ext. Coverage Horizontal Sidewall TFP230 56 TY6137 EC-14 14.0k (K200) Ext. Coverage Upright TFP220 57 67 TY6226 ESFR-1 14.0k (K200) ESFR Pendent TFP318 35 71 TY6236 ESFR-14 14.0k (K200) ESFR Pendent TFP319 36 72 TY6237 EC-14 14.0k (K200) Ext. Coverage Pendent TFP220 58 68 TY7103 Ultra K17 16.8k (K240) … camping bridport tasmania